Call 08047551720 74% Response Rate

our range

Voltage Monitoring Relay

Pioneers in the industry, we offer alternator volt relay 3p 3w from India.
  • Alternator volt relay 3P 3W
  • Alternator volt relay 3P 3W
  • Alternator volt relay 3P 3W
  • Alternator volt relay 3P 3W
Alternator volt relay 3P 3W

Alternator volt relay 3P 3W

Rs 1,400  / PieceGet Best Price

Minimum Order Quantity: 6 Piece

Number of Poles5 Pole
TypeHigh Voltage Relay
Voltage415V
Contact FormSPDT
Coil TypeNon Latching
Country of OriginMade in India
Product Specifications
Usage/Application      KaryteckBrand                       Schneider ElectricType                         High Voltage RelayNumber Of Poles        2 PoleContact Form             DPDTCoil Type                   Latching

Product Description
Features
Adjustable ON/Trip Time (1-15sec) delay provided.Common setting for all the phases.Factory set ON/OFF Voltage differential (Back-lash)Unaffected by frequency variations.Positive action without chattering.Both Din rail & Screw mounting provided.Life time guarantee of the unit (conditions apply)

Description
This is a compact micro-electronic device based on latest technology. It senses the voltage supply at its terminals and operates electromagnetic relay. The relay gets energized when all the phases are above the set value and gets de-energized when any of the phases goes below the set voltage value minus’ ON / OFF’ differential voltage (back-lash).
For Model Mini AVR, differential voltage is factory set (7V for 1phase & 10V for 3phase)Adjustable ON & OFF-Time delays is provided for protection against transients. Voltage setting and time delay are continuously adjustable with the help of a knob over a linear calibrated dial. Two changes are provided for customer’s usage. Auxiliary supply of 12VDC or 24VDC can be provided if required. Three LED’s (Light Emitting Diodes) are provided on top of the unit to indicate ‘Voltage supply on’,Relay on’ and ‘Under voltage’ condition.
Standard Models
Three Phase With Neutral-3pn
Voltage Setting 170-220ON/OFF Differential (backlash):7 VoltsOn Time Delay 1-15 SecondsOff Time Delay 1-15 Seconds.

Three Phase Without Neutral-3pVoltage Setting 300-400 VACON/OFF Differential (back-lash):10 VoltsOn Time Delay 1-15 SecondsOff Time Delay 1-15 Seconds.
Two Phase-2pVoltage Setting 300-400 VACON/OFF Differential (backlash):10 VoltsOn Time Delay 1-15 SecondsOff Time Delay 1-15 Seconds.
Two Phase-1p
Voltage Setting 170-220 VACON/OFF Differential (backlash):7 VoltsOn Time Delay 1-15 SecondsOff Time Delay 1-15 Seconds.

Setting / Repeat Accuracy± 2% of the time and voltage setting.
Maximum Permissible Operating Voltage550 VAC for three / two phase system.300 VAC for one phase system.
Burden10VA (maximum)
InsulationThe unit will withstand 2.5 KV 50 HZ for one minute between all A.C. Supply terminals and relay connected together and body.
Relay Contact Rating
6 Amps resistive load or 2 Amps inductive load at 230 VAC/440 VAC or 24
VDC
Dimension
Model Mini AVR : Height 105mm, Base 52 mm x 102 mmStandard AVR : Height 105mm, Base 67mm x 102mm